ATR 42-320 PK-YRP — Sepinggan Airport, Balikpapan

Nomor investigasi
KNKT.10.02.04.04
Waktu kejadian
Lokasi
Sepinggan Airport, Balikpapan
Wilayah administratif
KOTA BALIKPAPAN, KALIMANTAN TIMUR

Kronologi & deskripsi kejadian

The aircraft was departured from Kalimarau airport, Berau, East Kalimantan to Termindung Airport, Samarinda, East Kalimantan. ATS Balikpapan informed to ATS Berau that the aircraft divert to Balikpapan due to one engine failed.

Data teknis

Data teknis kejadian ATR 42-320 PK-YRP — Sepinggan Airport, Balikpapan
Operator / maskapai Trigana Air Service
Registrasi PK-YRP
Tipe pesawat ATR 42-320
MTOW above 5,700 kg
Tahun pembuatan 1987
Tipe operasi AOC 121
Fase penerbangan Landing (LDG)
Jenis kejadian System/Component Failure or Malfunction (Powerplant)
Jenis kejadian II Engine Flame-out

Korban

1 orang Luka berat

Faktor penyebab & kontributor

Faktor I
Technical

Sarana & operator terkait

Daftar sarana dan operator yang terlibat
Operator Flight Number Registrasi Tipe Pesawat Mtow Tahun Pembuatan Tipe Operasi
Trigana Air Service PK-YRP ATR 42-320 above 5,700 kg 1987 AOC 121

Rekomendasi keselamatan yang diterbitkan

Penerima: Directorate General of Civil Aviation

  • OPEN 0 tanggapan

    Ensure that FDR and CVR read out are correct from the actual last flight data, during C of A renewal.

    Lihat butir & lini masa tanggapan
  • OPEN 0 tanggapan

    Ensure the quality system of the operator was function as required by the regulation, in order to avoid such wing tank sealant uncured and dirt.

    Lihat butir & lini masa tanggapan

Penerima: Trigana Air Services

  • OPEN 0 tanggapan

    Ensure that the wing tank is clean and free from debris.

    Lihat butir & lini masa tanggapan
  • OPEN 0 tanggapan

    Ensure the actual of fuel quantity on both fuel tanks was equal and balance prior departure.

    Lihat butir & lini masa tanggapan
  • OPEN 0 tanggapan

    Ensure the FDR and CVR read out and calibration in accordance to the manufacture standard and should be done by approved repair station.

    Lihat butir & lini masa tanggapan
  • OPEN 0 tanggapan

    Ensure that the modification of fuel system referred to service bulletin No ATR42-28-039 and technical instruction No: 006/ENG-07/2008, was tested referred to the correct procedure as per AMM (JIC) 28-42-00 FUT 10000.

    Lihat butir & lini masa tanggapan
  • OPEN 0 tanggapan

    Review and improve the Implementation of CRM and technical knowledge.

    Lihat butir & lini masa tanggapan
  • OPEN 0 tanggapan

    Ensure that the correct sealant type for the wing tank application and correct procedure to be followed to avoid uncured process of it.

    Lihat butir & lini masa tanggapan